VGPSPL

 

Use Gas - Domestic Gas Meters - Mechanical Gas Meters


MTM1 MECHANICAL GAS METER


SPECIFICATION:
Case: Die cast aluminum body
Nominal flow-rate (Qn): 1 m3/h
Maximum flow-rate (Qmax): 1.6 m3/h
Minimum flow-rate (Qmin): 0.016 m3/h
Total pressure absorption: ≤160 Pa
Operation pressure range: 0.5~30 kPa
Cyclic volume: 0.7 l/rev.
Permissible error: Qmin≤Q<0.1Qmax ± 3%
                               0.1Qmax≤Q≤Qmax ±1.5%
Min. recording reading: 0.2 dm3
Max. recording reading: 9999.999 m3
Operation ambient temperature: -20°C+40°C
Service life: ≥10years
Storage temperature: -20~+50°C
Central distance: 130 mm
Connection thread: M30x2mm (or by customized)
Dimension: H234xW174xD123 mm
Weight: 1.95kg
Surface: Polyester powder plastics coating (gray)
Note: Printed index cover of polycarbonate